Configuration Frame relay simple en back to back avec une liaison serial
- R1 est DTE
- R2 est DCE (clock rate)
Remarque :
dans cette configuration, en l’absence de nuage FrameRelay, l’envoie de paquets LMI doit être désactivé « no keepalive »
Un DLCI est utilisé entre R1 et R2, un autre entre R2 et R1 ( mais un seul DLCI aurait pu être utilisé)
Configuration
R1#show run int s0/1 interface Serial0/1 ip address 200.1.1.1 255.255.255.0 encapsulation frame-relay no keepalive frame-relay map ip 200.1.1.3 303 frame-relay interface-dlci 113 end
R3#show run int s1/2 interface Serial1/2 ip address 200.1.1.3 255.255.255.0 encapsulation frame-relay no keepalive clock rate 64000 frame-relay map ip 200.1.1.1 113 frame-relay interface-dlci 303 end
Vérifications
R3#sh frame map Serial1/2 (up): ip 200.1.1.1 dlci 113(0x71,0x1C10), static, CISCO
R3#debug frame-relay packet Frame Relay packet debugging is on *Mar 6 08:30:16.911: Serial1/2(i): dlci 303(0x48F1), pkt type 0x800, datagramsize 104 *Mar 6 08:30:16.911: Serial1/2(o): dlci 113(0x1C11), pkt type 0x800(IP), datagramsize 104 *Mar 6 08:30:16.943: Serial1/2(i): dlci 303(0x48F1), pkt type 0x800, datagramsize 104 *Mar 6 08:30:16.943: Serial1/2(o): dlci 113(0x1C11), pkt type 0x800(IP), datagramsize 104 *Mar 6 08:30:16.975: Serial1/2(i): dlci 303(0x48F1), pkt type 0x800, datagramsize 104 *Mar 6 08:30:16.975: Serial1/2(o): dlci 113(0x1C11), pkt type 0x800(IP), datagramsize 104 *Mar 6 08:30:17.007: Serial1/2(i): dlci 303(0x48F1), pkt type 0x800, datagramsize 104 *Mar 6 08:30:17.011: Serial1/2(o): dlci 113(0x1C11), pkt type 0x800(IP), datagramsize 104 *Mar 6 08:30:17.043: Serial1/2(i): dlci 303(0x48F1), pkt type 0x800, datagramsize 104 *Mar 6 08:30:17.043: Serial1/2(o): dlci 113(0x1C11), pkt type 0x800(IP), datagramsize 104 *Mar 6 08:30:27.651: Serial1/2(i): dlci 303(0x48F1), pkt type 0x800, datagramsize 104 *Mar 6 08:30:27.651: Serial1/2(o): dlci 113(0x1C11), pkt type 0x800(IP), datagramsize 104 *Mar 6 08:30:27.683: Serial1/2(i): dlci 303(0x48F1), pkt type 0x800, datagramsize 104